Mosquito Magnet Executive Spécifications Page 3

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 36
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 2
4
Parts Included
Bug Bag
Quick Clear Adapter
Principal Parts
Self-Contained
Executive
Regulator Hose (1)
M
O
D
E
A
T
T
E
N
T
I
O
N
O
F
F
R
U
N
C
O
O
L
W A
R
M
M
O
D
E
Power Head (1)
Trumpet (1)
Support Pole (1)
Base Support (1)
Remote Battery Charger
Rechargeable Battery
3
Safety Instructions
Maintain adequate clearances of 51 cm - 61 cm around air openings
into the combustion chamber, clearances from combustible material,
provisions for accessibility and for combustion and ventilating air
supply. Keep the trap area clear and free from combustible materials,
gasoline, and other flammable vapors and liquids. The appliance is
not to be used in locations where flammable vapor or explosive dust
is likely to exist.
Do not obstruct the flow of combustion and ventilation air.
Keep the ventilating openings of the cylinder enclosure free and clear from debris.
Clean the trap with a water damp cloth, if necessary.
The LP-Gas cylinder must be provided with a shut-off valve terminating
in an LP-Gas supply cylinder valve outlet specified for Connection No.
510 in the Standard for Compressed Gas Cylinder Valve Outlet and Inlet
Connections, ANSI/CGA-V-1-1977.
The LP-Gas cylinder supply system must be arranged for vapor withdrawal
and the cylinder must include a collar to protect the cylinder valve.
The LP-Gas cylinder used shall be constructed and marked in accordance
with the specifications for LP-Gas cylinders of the U.S. Department of
Transportation (DOT) or The National Standard of Canada CAN/CSA-B339.
The trap shall be used outdoors only in a well ventilated space and shall
not be used in a building, garage, or any other enclosed area.
The LP-Gas cylinder must be disconnected and removed from the
appliance, if the appliance is stored indoors.
LP-Gas cylinders must be stored outdoors in a well-ventilated area out
of reach of children.
Disconnected cylinders must have threaded valve plugs tightly installed
and must not be stored in a building, garage, or any other enclosed area.
The pressure regulator and hose assembly supplied with this appliance
must be used for connection to the LP-Gas cylinder. Replacement pressure
regulators and hose assemblies must be specified by the manufacturer.
Avoid improper use of extension cords. Keep connections away from
moisture and avoid damage to the cord.
If the supply cord is damaged, it must be replaced by the manufacturer or
its service agent or a similarly qualified person in order to avoid hazard.
Visit www.mosquitomagnet.com
Children and adults should be alerted to the
hazards of high surface temperatures and should
stay away to avoid burns or clothing ignition.
Young children should be carefully supervised when they
are in the area of the heater. Keep out of reach of children.
Clothing or other flammable materials should not be
hung from the heater, or placed on or near the heater.
Please read and follow all safety
instructions and warnings.
Note:
Some or all of the following required safety instructions for
propane powered devices may apply to your trap. Allow
trap to cool for 5 minutes before re-starting.
Warning: Improper installation, adjustment, alteration,
service or maintenance can cause injury or property damage.
Read the installation, operating and maintenance instructions
thoroughly before installing or servicing the trap.
Caution: The gas pressure regulator provided with this
appliance must be used. This regulator is set for an outlet pressure
of 11.0 in. Water Column. The minimum inlet gas supply pressure is
11.0 in. Water Column from regulator.
This unit is not intended to be installed in or on recreational vehicles and/or boats.
The gas supply must be turned off at the LP-Gas supply cylinder when
this appliance is not in use.
The installation must conform with local codes or, in the absence of
local codes, with the National Fuel Gas Code, ANSI Z223. 1-1998 for US
and with the CAN1-B149 for Canada.
To test for a gas leak, place soapy water around the connector,
regulator, and gas hose assembly. If bubbles appear, there is a gas leak.
Inspect the hose before each use of the unit. If it is evident there is
excessive abrasion or wear, or the hose is cut, it must be replaced prior
to the unit being put into operation. The replacement hose shall be that
specified by the manufacturer.
The trap is equipped with an internal spark. Failure to follow starting
procedure will result in the trap not starting.
Installation and repair should be done by a qualified service person
(find service centers on www.mosquitomagnet.com). The heater should
be inspected before use and at least annually by a qualified service
person. More frequent cleaning may be required as necessary. It is
imperative that the control compartment, burners, and circulating air
passageways of the heater be kept clean.
Vue de la page 2
1 2 3 4 5 6 7 8 ... 35 36

Commentaires sur ces manuels

Pas de commentaire